1、先参考接线端子接线图,了解每个端子的作用及接线要求,再正确接线;确认接线无误后,用500V兆欧表或摇表测试绝缘电阻;要求电源接线子电机接线端子对机壳及相互间绝缘电阻值不小于300MΩ;若绝缘电阻符合规定方可进行通电调试工作。
1. First refer to the wiring diagram of the wiring terminal to understand the function and wiring requirements of each terminal, and then connect correctly; After confirming that the wiring is correct, test the insulation resistance with 500V megger or megger; It is required that the insulation resistance between the power connector and the motor terminal to the casing and each other shall not be less than 300m Ω; If the insulation resistance meets the requirements, power on commissioning can be carried out.
2、接通电源查看“正常”指示灯是否亮,若不亮(控制回路没电)应调换电源进线中任意两相;手动控制卷帘门上行、下行、停止及行程开关的调整;在无火警的情况下,按“上”按钮,卷帘门应下行;按“停”按钮,卷帘门应停止运行。试运行时,有可能上、下不符,此时只需任意调换两根起闭机的三相接线即可。随后试同运行方向相对应的限位是否起作用(用手直接触动微动开关),不起作用时应调换限位接线;接着调整好行程开关位置,使防火卷帘门开闭到位。
2. Turn on the power and check whether the "normal" indicator light is on. If it is not on (the control circuit is dead), replace any two phases in the power incoming line; Manually control the up, down, stop and travel switch adjustment of the rolling shutter door; In case of "no fire alarm", press the "up" button, and press the "down" button; Press the "stop" button to stop the rolling shutter door. During trial operation, there may be inconsistency between the upper and lower parts. At this time, it is only necessary to arbitrarily replace the three-phase wiring of two hoists. Then test whether the limit corresponding to the operation direction works (touch the microswitch directly by hand). If it doesn't work, replace the limit wiring; Then adjust the position of the travel switch to make the fireproof rolling shutter door open and close in place.
卷帘门组成防火卷帘门主要由防火卷帘帘体和电控系统。电控系统包括电控箱、熔断器、防火电机。帘面采用无机耐火布、硅酸铝纤维毯、防辐射布和装饰布经高温线缝制而成,双面用镀锌钢制条夹制,确保帘布的抗风强度,底箱封板为钢质镀锌,厚 度0.8㎜,无接缝。无缝钢管,管壁外经除锈防腐处理。 导轨采用钢质镀锌厚度1.2,采用分体复合制作。
The fire rolling shutter door is mainly composed of the fire rolling shutter body and the electric control system. The electric control system includes electric control box, fuse and fireproof motor. The curtain surface is made of inorganic refractory cloth, aluminum silicate fiber blanket, radiation protection cloth and decorative cloth through high-temperature thread. Both sides are clamped with galvanized steel strips to ensure the wind resistance of the curtain. The bottom box sealing plate is steel galvanized, with a thickness of 0.8mm and no joints. Seamless steel pipe, derusting and anti-corrosion treatment outside the pipe wall. The guide rail is made of steel with galvanized thickness of 1.2 and is made of split composite.
卷帘门可独立控制并具有手动功能,与温度熔断装置联动,与消防中控室直接进行联动。实现烟感报警,卷帘自动下降地面1.5-1.8m高度,延时180秒(可 调)然后在下降关闭。当下降时遇到障碍物可停止下降并上升。可实现烟感报警一次下滑,温感报警二次下滑,且温感报警后可停止二次下滑,可在一个系统内互相转换。卷帘配断链保护装置,以保护卷帘的可靠,确保安 全。
The rolling shutter door can be controlled independently and has a manual function. It is linked with the temperature fuse device and directly linked with the central fire control room. Realize the smoke alarm, and the rolling shutter will automatically descend to the height of 1.5-1.8m on the ground, with a delay of 180 seconds (adjustable), and then close when descending. When falling, it can stop falling and rise when encountering obstacles. It can realize the primary decline of smoke alarm and the secondary decline of temperature alarm. After the temperature alarm is eliminated, the secondary decline can be stopped and can be converted to each other in one system. The roller shutter is equipped with chain breaking protection device to protect the reliability of the roller shutter and ensure safety.
卷帘门电控箱注意事项:1、为安 全起见,控制器必 须接好地线!2、限位开关没有调整以前在无人监控状态下,电控箱不可处于通电状态;3、电控箱正式投入运行后,每月应进行一次运行检查;4、按键指令门不动作,先检查三相电源是否缺相,三相电源进线的相序是否接错,停止键是否接在常开触点上。
Precautions for electric cabinet of rolling shutter door: 1. For safety, the controller must be grounded! 2. Before the limit switch is adjusted, the electric control box cannot be powered on under the condition of unattended monitoring; 3. After the electric cabinet is officially put into operation, the operation inspection shall be conducted once a month; 4. If the key command door does not act, first check whether the three-phase power supply lacks phase, whether the phase sequence of the incoming line of the three-phase power supply is connected incorrectly, and whether the stop key is connected to the normally open contact.
以上就是今天带给大家的知识济南卷帘门专注行业多年,为用户不断的提供有价值的内容,更多内容请继续关注我们:http://www.jnzxmy.com
The above is the knowledge brought to you today. Jinan roller shutter door has focused on the industry for many years and continuously provides users with valuable content. Please continue to pay attention to us for more content: http://www.jnzxmy.com
1. First refer to the wiring diagram of the wiring terminal to understand the function and wiring requirements of each terminal, and then connect correctly; After confirming that the wiring is correct, test the insulation resistance with 500V megger or megger; It is required that the insulation resistance between the power connector and the motor terminal to the casing and each other shall not be less than 300m Ω; If the insulation resistance meets the requirements, power on commissioning can be carried out.
2、接通电源查看“正常”指示灯是否亮,若不亮(控制回路没电)应调换电源进线中任意两相;手动控制卷帘门上行、下行、停止及行程开关的调整;在无火警的情况下,按“上”按钮,卷帘门应下行;按“停”按钮,卷帘门应停止运行。试运行时,有可能上、下不符,此时只需任意调换两根起闭机的三相接线即可。随后试同运行方向相对应的限位是否起作用(用手直接触动微动开关),不起作用时应调换限位接线;接着调整好行程开关位置,使防火卷帘门开闭到位。
2. Turn on the power and check whether the "normal" indicator light is on. If it is not on (the control circuit is dead), replace any two phases in the power incoming line; Manually control the up, down, stop and travel switch adjustment of the rolling shutter door; In case of "no fire alarm", press the "up" button, and press the "down" button; Press the "stop" button to stop the rolling shutter door. During trial operation, there may be inconsistency between the upper and lower parts. At this time, it is only necessary to arbitrarily replace the three-phase wiring of two hoists. Then test whether the limit corresponding to the operation direction works (touch the microswitch directly by hand). If it doesn't work, replace the limit wiring; Then adjust the position of the travel switch to make the fireproof rolling shutter door open and close in place.
卷帘门组成防火卷帘门主要由防火卷帘帘体和电控系统。电控系统包括电控箱、熔断器、防火电机。帘面采用无机耐火布、硅酸铝纤维毯、防辐射布和装饰布经高温线缝制而成,双面用镀锌钢制条夹制,确保帘布的抗风强度,底箱封板为钢质镀锌,厚 度0.8㎜,无接缝。无缝钢管,管壁外经除锈防腐处理。 导轨采用钢质镀锌厚度1.2,采用分体复合制作。
The fire rolling shutter door is mainly composed of the fire rolling shutter body and the electric control system. The electric control system includes electric control box, fuse and fireproof motor. The curtain surface is made of inorganic refractory cloth, aluminum silicate fiber blanket, radiation protection cloth and decorative cloth through high-temperature thread. Both sides are clamped with galvanized steel strips to ensure the wind resistance of the curtain. The bottom box sealing plate is steel galvanized, with a thickness of 0.8mm and no joints. Seamless steel pipe, derusting and anti-corrosion treatment outside the pipe wall. The guide rail is made of steel with galvanized thickness of 1.2 and is made of split composite.
卷帘门可独立控制并具有手动功能,与温度熔断装置联动,与消防中控室直接进行联动。实现烟感报警,卷帘自动下降地面1.5-1.8m高度,延时180秒(可 调)然后在下降关闭。当下降时遇到障碍物可停止下降并上升。可实现烟感报警一次下滑,温感报警二次下滑,且温感报警后可停止二次下滑,可在一个系统内互相转换。卷帘配断链保护装置,以保护卷帘的可靠,确保安 全。
The rolling shutter door can be controlled independently and has a manual function. It is linked with the temperature fuse device and directly linked with the central fire control room. Realize the smoke alarm, and the rolling shutter will automatically descend to the height of 1.5-1.8m on the ground, with a delay of 180 seconds (adjustable), and then close when descending. When falling, it can stop falling and rise when encountering obstacles. It can realize the primary decline of smoke alarm and the secondary decline of temperature alarm. After the temperature alarm is eliminated, the secondary decline can be stopped and can be converted to each other in one system. The roller shutter is equipped with chain breaking protection device to protect the reliability of the roller shutter and ensure safety.
卷帘门电控箱注意事项:1、为安 全起见,控制器必 须接好地线!2、限位开关没有调整以前在无人监控状态下,电控箱不可处于通电状态;3、电控箱正式投入运行后,每月应进行一次运行检查;4、按键指令门不动作,先检查三相电源是否缺相,三相电源进线的相序是否接错,停止键是否接在常开触点上。
Precautions for electric cabinet of rolling shutter door: 1. For safety, the controller must be grounded! 2. Before the limit switch is adjusted, the electric control box cannot be powered on under the condition of unattended monitoring; 3. After the electric cabinet is officially put into operation, the operation inspection shall be conducted once a month; 4. If the key command door does not act, first check whether the three-phase power supply lacks phase, whether the phase sequence of the incoming line of the three-phase power supply is connected incorrectly, and whether the stop key is connected to the normally open contact.
以上就是今天带给大家的知识济南卷帘门专注行业多年,为用户不断的提供有价值的内容,更多内容请继续关注我们:http://www.jnzxmy.com
The above is the knowledge brought to you today. Jinan roller shutter door has focused on the industry for many years and continuously provides users with valuable content. Please continue to pay attention to us for more content: http://www.jnzxmy.com
下一篇:济南卷帘门系统使用中怎么维护? 上一篇:工业滑升门应用小常识
阅读/ Recommended reading
- 济南卷帘门10 2024-12-03
- 车库卷帘门故障及维修方法 2024-12-14
- 车库卷帘门的维修和保养方法有哪些 2024-12-07
- 济南卷帘门:门锁上了该怎么解锁? 2024-11-23
- 济南卷帘门:断掉一片后的处理方法,你学会了吗? 2024-11-19
- 如何延长卷闸门的寿命 2024-11-06
- 重视卷帘门门口堆物问题 2024-11-06
- 快速卷帘门介绍与快速卷帘门材料说明 2024-10-26
济南卷帘门的工作原理及安装维修
2024-12-18
济南卷帘门在家庭、商业和工业建筑中得到了广泛应用,其功能齐全、可靠、美观实用的特点使其成为门窗装饰的材料。济南卷帘门采用高强度铝合金材料,具备抗风、抗撞击和防盗特性,并配备...